ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/T - C5 and AOD - New Sealant On Case Bolts|Page 3758 > < A/T - C5 and AOD - New Sealant On Case Bolts
Page 2
background image

FIGURE 10

On the C5 transmission, the three (3) bottom pump and converter housing to case bolts (small flange case) were precoated with the sealant to prevent oil
leaks. (Refer to Figure 10 for the location of the bolts.) On the AOD transmission, all the pump to case bolts were precoated with the Dri-Loc sealant.
For this reason, more break torque might be required to remove the bolts.
When service requires removing and reinstalling the bolts, wire brush the bolts and the case bolt holes. Remove as much loose sealant as possible.
Recoat the bolt with either Threadlock and Sealer (Part No. E0AZ- 19554-A), Pipe Sealant with Teflon (Part No. D8AZ- 19554-A), or Teflon tape.
Torque the bolts to specification. (The torque specification has not changed, C5- 28-38 lbs.ft.; AOD-16-20 lbs.ft.).

PART NUMBER

PART NAME

CLASS

E0AZ-19554-A

Threadlock and Sealer

AG

D8AZ-19554-A

Pipe Sealant with Teflon

AG

OTHER APPLICABLE ARTICLES: None

A/T - C5 and AOD - New Sealant On Case Bolts|Page 3758 > < A/T - C5 and AOD - New Sealant On Case Bolts