ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

With Automatic Temperature Control|Page 6518 > < With Automatic Temperature Control
Page 2
background image

ATC Temperature Control Cable Routing

9. Note cable routing and remove cable from vehicle.

INSTALLATION

1. Route the cable behind the instrument panel and connect the cable to the sensor.

NOTE:  Do not tighten the attaching screw at this time.

2. Connect the other end of the control cable to the temperature lever arm of the control assembly. Snap the cable housing into place at the control

assembly.

3. Install a new push nut to retain the cable end loop on the temperature lever arm.
4. Position the control assembly to the instrument panel and install the four attaching screws.
5. Position the center finish panel to the instrument panel and install the two attaching screws.
6. Install the knobs on the radio control shafts.
7. Adjust the temperature control cable.
8. Install the instrument panel pad.
9. Connect the ground cable to the battery negative (-) terminal.

NOTE:  On vehicles equipped with Electronic Engine Control (EEC), when the battery has been disconnected and reconnected, some abnormal
drive symptoms may occur while the EEC processor relearns its adaptive strategy. The vehicle may need to be driven 10 miles or more to relearn
the strategy.

10. Check the system for proper operation.

With Automatic Temperature Control|Page 6518 > < With Automatic Temperature Control