FLOOR
With the function lever in the FLOOR position, the airflow is directed to the floor outlets with a slight amount directed to the windshield through
the defroster outlets.

MIX
With the function lever in the MIX position, the airflow is divided between the defroster outlets and floor ducts. The door positioning is similar to
FLOOR except the floor defrost door is in mid-position (partial vacuum) to provide the airflow split.

DEFROST
When the function lever is in the DEFROST position, the panel door and the floor-defrost door are in the full defrost (no vacuum) positions so that
all incoming air is directed to the defroster nozzles with a slight bleed to the floor. Maximum heat is obtained by moving the temperature lever to
the highest temperature (WARM) position.

Coolant Temperature Sensor / Switch HVAC > < With Air Conditioning|Page 6620