ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

TFI Module - No Start/Intermittent Run|Page 5182 > < TFI Module - No Start/Intermittent Run
Page 2
background image

Figure 7

For the above customer concern, visually inspect the T.F.I. ignition module to determine if the plastic housing has partially separated from the metal base
plate next to the connector (Figure 7). If the module has separated replace it. Coat the metal base plate of the T.F.I. module with silicon compound
(D7AZ-19A331-A or equivalent), approximately 1/32 inch thick. Tighten the mounting screws to 2.5-2.8 N-m of torque. This concern can be caused if
the module is used as a handle for adjusting or moving the distributor.
PART NUMBER

PART NAME

CLASS

D7AZ-19A331-A

Silicon Compound

A

OTHER APPLICABLE ARTICLES: None
WARRANTY STATUS: Reimbursable within the provisions of the Warranty and Policy Manual.

TFI Module - No Start/Intermittent Run|Page 5182 > < TFI Module - No Start/Intermittent Run