ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Procedures|Page 1466 > < Procedures
Page 1
background image

Variable Valve Timing Cover / Housing: Removal and Replacement

Variable Camshaft Timing (VCT) Housing

Removal

All Variable Camshaft Timing (VCT) housings

1. Remove the timing drive components. For additional information, refer to Timing Drive Components  See: Timing Components/Service and

Repair/Removal and Replacement/Timing Drive Components.

RH VCT housing

2. Remove the 2 bolts and the RH Variable Camshaft Timing (VCT) housing.

LH VCT housing

3. Remove the 2 bolts and the LH VCT housing.

All VCT housings

4. Remove and discard the VCT housing gasket.

5. NOTICE: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These tools

cause scratches and gouges which make leak paths. Use a plastic scraping tool to remove all traces of old sealant.

Clean and inspect the cylinder head sealing surfaces with metal surface prep. Follow the directions on the packaging.

6. Clean and inspect the VCT housing.

Installation

All VCT housing

Procedures|Page 1466 > < Procedures