11. Install the 2 RH catalytic converter-to-exhaust manifold nuts.

-

Tighten to 40 Nm (30 lb-ft).

12. NOTE: Make sure the B+ cable is positioned close to the generator when the nut is being tightened.

Position the generator and install the B+ terminal and nut.

-

Tighten to 8 Nm (71 lb-in).

13. Connect the generator electrical connector and pin-type retainers.

14. Install the 2 lower generator nuts.

-

Tighten to 25 Nm (18 lb-ft).

15. Install the 2 outer generator bracket bolts.

-

Tighten to 10 Nm (89 lb-in).

16. Using a suitable belt tensioner release tool, rotate the accessory drive belt tensioner clockwise and position the accessory drive belt onto the

generator pulley.

17. Install the radiator sight shield and 6 pin-type retainers.

18. Install the starter.

19. Install the TB.

20. Install the ACL assembly.

21. Connect the battery ground cable.