Mustang V8-4.6L (2009)
Variable Valve Timing Solenoid: Service and Repair
Variable Camshaft Timing (VCT) Oil Control Solenoid - 4.6L (3V)
Removal and Installation
1. Remove the LH or RH valve cover.
2. Remove the bolt and the Variable Camshaft Timing (VCT) oil control solenoid.
-
To install, tighten to 5 Nm (44 lb-in).
3. To install, reverse the removal procedure.