Accumulator HVAC: Description and Operation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

In addition to the preceding condition, a new suction accumulator should be installed if one of the following conditions exist:

-

The suction accumulator is perforated.

-

The refrigerant system has been opened to the atmosphere for a period of time longer than required to make a minor repair.

-

There is evidence of moisture in the system such as internal corrosion of metal refrigerant lines or the refrigerant oil is thick and dark.

The suction accumulator is mounted to the A/C accumulator bracket to the right of the vehicle centerline. The inlet tube of the suction accumulator
attaches directly to the A/C evaporator core outlet tube and the outlet tube attaches to the A/C manifold and tube.

After entering the inlet of the suction accumulator, the heavier oil-laden refrigerant contacts an internally mounted dome (which serves as an umbrella)
and drips down onto the bottom of the canister.

-

A small diameter oil bleed hole, in the bottom of the vapor return tube, allows the accumulated heavier liquid refrigerant and oil mixture to reenter