Hose/Line HVAC: Service and Repair
Suction Accumulator to Compressor Line

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

REMOVAL

1. Recover the refrigerant. Refer to:  Heating and Air Conditioning, Service and Repair, Refrigerant Discharging and Recovery Procedure, 

See: Heating and Air Conditioning/Service and Repair/Refrigerant Discharging and Recovery Procedure

2. Remove the air cleaner outlet tube. 

3. Disconnect the spring lock coupling at the suction accumulator.

-

Discard the O-ring seals.

4. Disconnect the spring lock coupling at the compressor manifold.

-

Discard the O-ring seals.

5. Remove the suction accumulator to compressor line.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean PAG oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test and charge the refrigerant system. Refer to:  Heating and Air Conditioning, Service and Repair, Evacuating and Charging,

See: Heating and Air Conditioning/Service and Repair/Evacuation and Charging