Mustang V8-4.6L DOHC VIN R (2003)
5. Disconnect the spring lock coupling at the compressor manifold and tube.
-
Discard the O-ring seals.
6. Remove the compressor to condenser discharge line.
INSTALLATION
1. To install, reverse the removal procedure.
-
Install new O-ring seals lubricated in clean PAG oil.
-
Lubricate the refrigerant system with the correct amount of clean PAG oil.
2. Evacuate, leak test and charge the refrigerant system. Refer to: Heating and Air Conditioning, Service and Repair, Evacuating and Charging,
See: Heating and Air Conditioning/Service and Repair/Evacuation and Charging