Page 4
background image

16. Position the wiring harness rearward.

17. Remove the condenser bolts.

18. Remove the condenser core.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean PAG oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test and charge the refrigerant system.