ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Relay Box > < Power Distribution Module|Service and Repair
Page 2
background image

3. NOTE:  The SJB electrical connector levers must click into a fully released position before they can be removed.

Disconnect the 2 front SJB electrical connectors.

4. Remove the SJB nut.
5. Slide the SJB downward and position the SJB forward to access the rear electrical connectors.

6. NOTE:  The SJB electrical connector levers must click into a fully released position before they can be removed.

Disconnect the 6 rear SJB electrical connectors and remove the SJB.

Installation

NOTE:  When a new SJB is installed, all customer remote keyless entry (RKE) transmitters may be required to be present in order to program the
RKE transmitters to the new SJB.

1. CAUTION:  Make sure the wiring harnesses are correctly routed. Pinching the wiring harnesses between the SJB and the mounting

surface may cause damage to the wiring harness.

NOTE:
-

Do not remove the watershield from the new SJB.

-

The SJB electrical connector levers must click into a fully closed (connected) position when installing.

Connect the 6 rear SJB electrical connectors and install the SJB.

2. Install the SJB nut.

-

Tighten to 6 Nm (53 lb-in).

3. NOTE:  The SJB electrical connector levers must click into a fully closed (connected) position when installing.

Connect the 2 front SJB electrical connectors by fully engaging the levers until an audible click is heard.

4. NOTE:  If the SJB was not replaced, the procedure is completed after this step. If the SJB was replaced, follow steps 4-7.

Install the RH A-pillar lower trim panel.

5. NOTE:

-

When successful, this step provides the calibration necessary for the SJB operation and clears the DTC B2477. The clearing of this DTC
indicates the calibration data has been successfully downloaded to the new SJB.

-

When successful, this step also programs the RKE transmitters into the new SJB. In the event the RKE transmitters do not program to the new
SJB, all of the RKE transmitters will need to be present and refer to Locks, Remote Keyless Entry Transmitter Programming. This action will
program the RKE transmitters into the new SJB.  See: Accessories and Optional Equipment/Antitheft and Alarm Systems/Keyless
Entry/Keyless Entry Transmitter/Testing and Inspection/Remote Keyless Entry Transmitter Programming

Download the SJB configuration information from the scan tool into the new SJB.

6. NOTE:  When successful, this step clears DTCs B2868, B2869, B2870, and B2871. The clearing of these DTCs indicates the SJB has recognized

the tire pressure sensors during the tire pressure sensor training procedure.

Train the tire pressure sensors.

7. NOTE:

-

This step is required to clear DTC C2780, allow the SJB to exit the manufacturing mode, and to be sure there are no other concerns with the
newly programmed SJB.

-

DTC C2780 will not clear if any of the other 5 manufacturing mode DTCs are present in the SJB.

Carry out the SJB on-demand self-test. Clear the DTCs and then retrieve the DTCs to confirm all DTCs have been cleared.

Relay Box > < Power Distribution Module|Service and Repair