Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
1. Remove TORX(R) head screw from black plastic cover and remove cover.
2. Remove 15 pin connector.
3. Remove 4 pin connector.
4. Remove six TORX(R) head bolts securing anti-lock brake control module to hydraulic control unit.
5. Remove anti-lock brake control module by pulling straight up over ground post.
REASSEMBLY
1. Position anti-lock brake control module over ground post.
2. Install six TORX(R) bolts and secure anti-lock brake control module to the hydraulic control unit.
3. Install 4 pin and 15 pin connector.
4. Install cover and secure with screw.
INSTALLATION
1. Install three nuts and mounting bracket on the hydraulic control unit and tighten nuts to 10-20 Nm (89-177 inch lbs.).
2. Install hydraulic control unit and four bolts. Tighten bottom bolts to 10-14 Nm (89-123 inch lbs.). Tighten remaining bolts to 18-26 Nm (14-19 ft.
lbs.).
3. Install hydraulic control unit ground wire and screw. Tighten to 3.4-4.8 Nm (30-42 inch lbs.).
4. Connect five brake tubes to hydraulic control unit.
5. Connect two wiring harnesses.
6. Connect battery ground cable.
NOTE: Service to the ABS valve block and pump and motor assembly does not require any special bleeding procedure. Follow manual or
pressure bleeding procedures.
7. Bleed brake system.