Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
9. Position ignition wires and connect two ignition wire separators to generator mounting bracket.
CAUTION: Use extreme care to keep coolant mixture off of accessory drive pulleys. If needed, remove drive belt (8620) and rinse with clear
water. Clean pulleys and install engine accessory drive belt. Drive belt squeal and early drive belt fatigue will occur otherwise.
10. Close radiator draincock (8115) and fill engine coolant.
11. Connect battery ground cable.
12. Start engine and check for leaks.