Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
Radiator Cooling Fan Control Module: Service and Repair
REMOVAL
1. Remove constant control relay module retaining nuts.
2. Remove engine control sensor wiring (12A581) from constant control relay module.
INSTALLATION
1. Follow removal procedure in reverse order.
2. Tighten retaining nuts to 8-12 Nm (6-8 ft. lbs.).