ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Receiver Dryer|Removal and Installation|Page 8591 > < Receiver Dryer|Specifications|Page 8588
Page 1
background image

Receiver Dryer: Service and Repair
Removal and Installation

SPECIAL SERVICE TOOL(S) REQUIRED 

Description  .......................................................................................................................................................................................... Tool Number 
Spring Lock Coupling Disconnect Tool (5/8 Inch) .............................................................................................................................  T83P-19623-C

REMOVAL 

1. Remove 8 push pins and radiator upper sight shield.
2. Recover the refrigerant from the A/C system. Observe all safety precautions.
3. Remove A/C cycling switch.
4. Disconnect the A/C manifold and tube at the suction accumulator/drier using Spring Lock Coupling Disconnect Tool T83P-19623-C or equivalent.

Cap the A/C manifold and tube and suction accumulator/drier to prevent the entrance of dirt and moisture.

5. Remove the nut holding the suction accumulator/drier in the A/C accumulator bracket.
6. Disconnect the suction accumulator/drier inlet tube from the A/C evaporator core outlet tube and remove the suction accumulator/drier.

INSTALLATION 

1. Position the suction accumulator/drier into the A/C accumulator bracket.
2. Using new O-rings lubricated with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B, connect

the suction accumulator/drier inlet tube to the A/C evaporator core outlet.

3. Install the nut on the A/C accumulator bracket. Tighten nut to 6.6-9.4 N.m (59-83 Lb-In).
4. Using new O-rings seal lubricated with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B,

connect the A/C manifold and tube to the suction accumulator/drier.

5. Install the A/C cycling switch and connect wire harness.
6. Leak-test, evacuate and charge the system following the recommended service procedures. Observe all safety precautions.  See: Service and

Repair

7. Install radiator upper sight shield. Check the system for proper operation.