Audible Warning Device Control Module: Initial Inspection and Diagnostic Overview

Inspection and Verification

1. Verify the customer's concern by operating the warning chime system to duplicate the condition.
2. Inspect to determine if one of the following electrical concerns apply:

VISUAL INSPECTION CHART 
 

Electrical

-

Check fuse junction panel Fuses 6 (15A) 15(10A), 5(15A) or 8(10A).

-

Check connectors for loose connection, damage. corrosion.

-

Check circuits for shorts/opens.

3.  If the inspection reveals obvious concerns that can be readily identified, service as required.
4. If the concern(s) remains after the inspection, determine the symptom(s) and  See: Symptom Related Diagnostic Procedures