ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Purge Flow Sensor, Evaporative System > < EGR DPFE Sensor - Voltage Range Revision|Page 779
Page 1
background image

Pressure Feedback Exhaust Sensor: Service and Repair

REMOVAL

1. Disconnect fuel charging wiring connector from pressure feedback exhaust sensor.
2. Disconnect hoses from pressure feedback exhaust sensor.
3. Remove retaining nuts and pressure feedback exhaust sensor from mounting bracket.
4. If necessary, remove the mounting bracket.

NOTE:  Remove the EGR tube heat shield.

INSTALLATION

1. Follow removal procedure in reverse order.
2. If removed, tighten retainers for the mounting bracket and EGR tube heat shield to 8-12 Nm (71-106 lb in). Tighten EGR retaining nuts to 5-7 Nm

(45-61 lb in). 

Purge Flow Sensor, Evaporative System > < EGR DPFE Sensor - Voltage Range Revision|Page 779