Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
Starter Solenoid: Testing and Inspection
Make sure that the starter solenoid is isolated electrically from the starter motor. Using an ohmmeter, measure resistance between S-terminal and
M-terminal, and between S-terminal and ground (starter frame and magnet). If resistance is greater than 0.08 Ohm the following conditions may exist:
^
Open wire; replace starter solenoid
^
Ice, dirt or other foreign material preventing contact; service as necessary
Solenoid S-Terminal Circuit Resistance
Check the resistance of the entire S-terminal circuit, including all the switches, wires and connections. Resistance should be less than 0.08 Ohm.
Solenoid M-Terminal
1. Measure resistance between the starter solenoid M-terminal and the starter solenoid housing.
2. If resistance is greater than 0.08 Ohm, replace the starter solenoid.