ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Shift Solenoid, A/T|Diagrams|Page 5811 > < Shift Interlock Switch|Description and Operation
Page 1
background image

Shift Solenoid: Diagrams

Chart #701

OPERATION 

Two ON/OFF shift solenoids are used for electronic shift scheduling. One unit containing the two shift solenoids is located in the main control
valve body. The shift solenoids are two-way, normally closed style. Shift solenoids 

(SS-1 and SS-2) provide gear selection of first through fourth

gears by controlling the pressure to the three shift valves. 

SHIFT SOLENOID FAILURE MODES 

Shift Solenoid Failure "Always On" 

Failed ON due to powertrain control module 

(PCM) and/or vehicle wiring concerns, shift solenoid electrically or hydraulically stuck ON.