REMOVAL
NOTE: If an A/C condenser core leak is suspected, the A/C condenser core must be leak tested before it is removed from the vehicle.
1. Disconnect and remove the battery. For additional information, refer to Battery.
2. Perform the Refrigerant Discharging and Recovery Procedure.
3. Remove the bolts and remove the battery tray.
4. Remove the coolant recovery bottle. For additional information, refer to Cooling System.
5. Remove the radiator sight shield.
-
Remove the pin-type retainers.
-
Remove the shield.
6. Disconnect the cooling fan electrical connector.