Mustang GT V8-4.6L SOHC VIN X (1998)
Air Door Actuator / Motor: Service and Repair
Air Inlet Door
REMOVAL
1. Remove instrument panel.
2. Remove A/C evaporator housing.
3. Remove vacuum control motor arm from A/C damper door cam.
4. Disconnect vacuum hose harness from vacuum control motor.
5. Remove two vacuum motor retaining screws.
6. Remove vacuum control motor.
INSTALLATION
1. Follow removal procedure in reverse order.