Mustang GT V8-4.6L SOHC VIN X (1998)
Refrigerant Pressure Sensor / Switch: Service and Repair
A/C Pressure Cut-Off Switch
REMOVAL
1. Disconnect pressure cut-off switch electrical connector.
2. Remove A/C pressure cut-off switch from A/C compressor to condenser discharge line.
INSTALLATION
1. Follow removal procedure in reverse order.
2. Use new O-ring seals lubricated with clean Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.