Multiplex Communication Network: Service and Repair

NOTE:  If either circuit 914 or circuit 915 is repaired without following the proper repair procedures, the operation of the Standard Corporate Protocol 
(SCP) communication network will be degraded.

Circuit 914 and circuit 915 must be twisted at a rate of 83-40 twists per 1.0 meter (3.3 feet) anytime replacement of either circuit is required. The twist
must be within 10 centimeters (4.9 inches) of any connector termination point.

The conductor for circuit 914 and circuit 915 must be No. 20 AWG wire.