Mustang GT V8-4.6L SOHC VIN X (1998)
Positive Crankcase Ventilation Valve: Service and Repair
REMOVAL
1. Remove air cleaner outlet tube.
2. Disconnect crankcase vent connector and hose from positive crankcase ventilation valve.
3. Remove positive crankcase ventilation valve from crankcase ventilation grommet in valve cover.
4. Inspect positive crankcase ventilation valve and crankcase ventilation grommet for deterioration. Replace if necessary.
INSTALLATION
1. Follow the removal procedure in reverse order.