Refrigerant Pressure Sensor / Switch: Pressure, Vacuum and Temperature Specifications

A/C Cycling Switch

Close ................................................................................................................................................................................................. 276-324 kPa (40-47 psi)
Open ................................................................................................................................................................................................. 152-193 kPa (22-28 psi)

A/C Pressure Cut-Off Switch

Compressor Control

Open ............................................................................................................................................................................... 2896 kPa (420 psi) Minimum
Close .............................................................................................................................................................................. 1724 kPa (250 psi) Maximum

Fan Control

Open ................................................................................................................................................................................................ 1896 kPa (275 psi)
Close ............................................................................................................................................................................................... 2241 kPa (325 psi)