Mustang GT V8-4.6L SOHC VIN X (1998)
Voltage Regulator: Service and Repair
REMOVAL
1. Remove the four screws (T20 TORX(R)-type head) retaining the voltage regulator to the generator (GEN).
2. Remove the voltage regulator, with generator brush and terminal holder attached, from the generator.
INSTALLATION
1. Install the voltage regulator and generator brush and terminal holder to the generator with four screws.
2. Tighten screws to 2.3-3.4 N.m (21-30 lb-in).