ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Wheel Tightening Sequence|Page 5286
Page 1
background image

Accumulator HVAC: Service and Repair

1.

Discharge refrigerant from system.

2.

Remove charcoal canister.

3.

Disconnect accumulator/dryer suction line at bulkhead, then remove compressor suction line from accumulator/dryer. Cap suction and evaporator
core outlet lines.

4.

Remove clutch cycling pressure switch electrical connector, then the two mounting bolts from accumulator/drier mounting bracket, and carefully
remove accumulator/drier from vehicle.

5.

Reverse procedure to install. Use new O-ring lubricated with refrigerant oil.

6.

Leak test, evacuate and charge system. 

Air Door, HVAC > < Wheel Tightening Sequence|Page 5286