ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - New O Ring Applications|Page 5542 > < A/C-Heater|Page 5536
Page 1
background image

A/C Coupler O-ring: Technical Service Bulletins
A/C - New O Ring Applications

Article No.
96-20-8

09/23/96

^

AIR CONDITIONING - NEW 0-RING APPLICATIONS - THICKER 0-RINGS FOR SPRING LOCK FITTINGS - SERVICE TIP

^

AIR CONDITIONING - SPRING LOCK COUPLING CLEANING PROCEDURE - SERVICE TIP

FORD:
1992-93 FESTIVA
1992-94 TEMPO
1992-97 CROWN VICTORIA, ESCORT, MUSTANG, PROBE, TAURUS, THUNDERBIRD
1994-97 ASPIRE
1995-97 CONTOUR

LINCOLN-MERCURY:
1991-94 CAPRI
1992 MARK VII
1992-94 TOPAZ
1992-97 CONTINENTAL, COUGAR, GRAND MARQUIS, SABLE, TOWN CAR, TRACER
1993-97 MARK VIII
1995-97 MYSTIQUE

LIGHT TRUCK:
1992-96 BRONCO
1992-97 AEROSTAR, ECONOLINE, EXPLORER, F SUPER DUTY, F-150-350 SERIES, F-47, RANGER
1993-97 VILLAGER
1995-97 WINDSTAR
1997 MOUNTAINEER

ISSUE: 
A new air conditioning spring lock coupling cleaning procedure has been developed. This procedure is required for a thicker O-ring that has been
released for servicing spring lock couplings. These O-rings have a larger cross-sectional diameter for improved sealing. The thicker O-ring is green in
color and identifiable only by the part number. These are service only O-rings and will not be used in production.

ACTION: 
Clean the Spring Lock Coupling(s) (SLC), if their service is required, and install the new thicker O-rings by referring to the following Service Procedure
for details.

SERVICE PROCEDURE

1.

Recover refrigerant from the A/C system.

2.

Disconnect SLC(s).

3.

Remove old O-rings using a plastic O-ring tool and discard. Plastic O-ring Service Tools are available from Rotunda in the R-134a/R-12 Port kit
(164R2602) or the 0-Ring Pick/Valve Core Removal Tool kit (164R2604). These items can be ordered by calling 1-800-768-8632 (Mon-Fri,
8AM-5PM EST). When prompted, press choice 2 for dealership supply orders.

4.

Check the female SLC O-ring sealing surface for scratches, corrosion, or debris from deteriorated O-rings. Clean any surface residue from the
inside of the couplings by using the following procedure (Steps 4a-4j):

a.

Obtain the following shop equipment and cleaning supplies locally:

^

3-1/2" length of steel brazing rod

^

YN-9 (mineral) oil for R-12 systems or YN-12-B (PAG) oil for R-134a systems

^

Variable speed electric drill

^

Safety goggles or glasses

A/C - New O Ring Applications|Page 5542 > < A/C-Heater|Page 5536