b.
Measure the distance between the "B" pillar weatherstrip surface and the outside of the glass. See Figure 7. This distance must be between
14-19 mm.
c.
To adjust, loosen the adjustment screw locknut, Figure 8, and turn the adjustment screw counter-clockwise to increase the distance.
d.
Tighten the adjustment screw locknut.
e.
Recheck the distance between the "B" pillar weatherstrip surface and the outside of the glass.
7.
Check the door glass front height adjustment. Adjust if necessary.