ford Workshop Repair Guides

Ford Puma Workshop Service and Repair Manuals | 1998 - 2001

412-00 Climate Control System - General Information|Description and Operation > < Accelerator Cable Adjustment
Climate Control System - General Information - Specifications Puma 1998 (06/1997-12/2001)

Fluids

Specification
Refrigerant R134a WSH-M17B19-A
Refrigerant oil for R134a WSH-M1C231-B

Fill Capacity

Grams
Air conditioning system refrigerant, quantity for first fill 740 g±15 g
Refrigeration system refrigerant, quantity for first fill 1000 g±15 g

Fill Capacity

Litres
Air conditioning system refrigerant oil, quantity for first fill 200 ml
Refrigeration system refrigerant oil, quantity for first fill 250 ml

Topping Up with Air Conditioning Refrigerant Oil (when components have been renewed)

Description Fill Capacity
Air conditioning compressor if the quantity of oil removed from the compressor is less than 90 ml Add 90 ml.
Air conditioning compressor if the quantity of oil removed from the compressor is between 90 ml and 148 ml Fill with the same quantity plus 30 ml.
Air conditioning compressor if the quantity of oil removed from the compressor is greater than 148 ml Add 148 ml.
Air conditioning condenser Add 30 ml
Air conditioning evaporator Add 90 ml
Dehydrator/accumulator Pour the oil from the air conditioning dehydrator/accumulator which is being renewed into a measuring cylinder. Refill the new dehydrator/accumulator with the same quantity of oil plus 90 ml.
Every time refrigerant is extracted Add 20 ml
When all lines and components are renewed Add 60 ml

Air conditioning magnetic clutch

Gap between the drive plate and the pulley 0.35 mm - 0.85 mm

Torque Specifications

Description Nm lb-ft lb-in
Heater to bulkhead 9 - 80
Pollen filter housing 5 - 44
Condenser to radiator 6 - 53
Collector/dehydrator to bracket 6 - 53
High pressure switch to refrigerant line 8 - 71
Compressor to bracket 25 18 -
Suction/pressure pipe to compressor 20 15 -
Radiator crossmember 25 18 -
Drivebelt tensioner lock bolt (1,8 diesel engine) 20 15 -
Drive plate to compressor (FS10) 13 10 -
Drive plate to compressor (FVS 090, diesel engine only) 17 30 -
Refrigerant line to additional oil reservoir - refrigeration system 23 17 -
Union nut - de-ice line (1/2") to evaporator - refrigeration system 14 10 -
Union nut - refrigerant line (3/8") to evaporator - refrigeration system 23 17 -
Union nut - refrigerant line (5/8") to evaporator - refrigeration system 33 25 -
Bolts for blower motor - refrigeration system 6 - 53
Bolts for evaporator cover - refrigeration system 6 - 53

Pressures - High Pressure Switch

bar
Air conditioning system on up to 22.4 (P1)
Air conditioning system off from 29.7 (P2)
High fan speed from 22.4 (P1)
Low fan speed up to 17.5 (P3)

Pressures - Low Pressure Switch

bar
Air conditioning system on from 2.9 (P4)
Air conditioning system off up to 1.6 (P5)

Fixed orifice tube

Colour of fixed orifice tube (green)

412-00 Climate Control System - General Information|Description and Operation > < Accelerator Cable Adjustment