ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Front Suspension - Rear Wheel Drive (RWD)|Page 4311
Page 1
background image

Accumulator HVAC: Service and Repair

Suction Accumulator

Removal and Installation

NOTE: Installation of a new suction accumulator is not required when repairing the A/C system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator. Damage to the suction accumulator includes leaks in the suction
accumulator, physical damage to the suction accumulator shell or desiccant, or moisture contamination. Moisture contamination results only from a
complete loss of refrigerant, and equalization of the refrigerant system pressure with atmospheric pressure for a period longer than one hour. If even a
slight amount of positive refrigerant pressure is present in the refrigerant system before repairs are carried out, the suction accumulator should not be
replaced.

1. Recover the refrigerant.

2. Disconnect the A/C cycling switch electrical connector.

3. NOTICE: Use a back-up wrench to prevent damage to the tubes.

Disconnect the suction accumulator inlet and outlet fittings.

-

Discard the O-ring seals.

-

To install, tighten the inlet fitting to 39 Nm (29 lb-ft).

4. Remove the suction accumulator bracket screws and the suction accumulator.

5. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil or equivalent.

6. Evacuate, leak test and charge the refrigerant system.

Air Door, HVAC > < Front Suspension - Rear Wheel Drive (RWD)|Page 4311