Is the resistance less than 5 ohms when the switch is released and greater than 10,000 ohms when the switch is pressed?

Yes

GO to C5.

No

INSTALL a new door ajar switch. TEST the system for normal operation.

-------------------------------------------------
C5 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. TEST the system for normal operation.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
self-test.

-------------------------------------------------

Pinpoint Test D: The Illuminated Entry Is Inoperative When Using the Remote Keyless Entry (RKE)
Transmitter

Interior Lighting

Pinpoint Tests

Pinpoint Test D: The Illuminated Entry Is Inoperative When Using The Remote Keyless Entry (RKE) Transmitter

Normal Operation

The illuminated entry provides interior lighting when the Smart Junction Box (SJB) receives an UNLOCK request from the Remote Keyless Entry
(RKE) transmitter. When the SJB receives the RKE signal, it activates the interior lamp relay (internal to the SJB) and applies voltage to circuit CLN28
(GN/BU).

This pinpoint test is intended to diagnose the following:

-

RKE system

-

SJB

PINPOINT TEST D: THE ILLUMINATED ENTRY IS INOPERATIVE WHEN USING THE RKE TRANSMITTER

-------------------------------------------------
D1 CHECK THE DOOR LOCK OPERATION USING THE RKE TRANSMITTER

Initial Inspection and Diagnostic Overview|Page 5616 > < Initial Inspection and Diagnostic Overview|Page 5614