Inspect the foam evaporator core seals for proper positioning (Figure 1).

6.

The seals are positioned on the blower wheel area as marked. There should be no gaps at either end of the seals. Witness marks should be present
along the entire length of the seals. If no marks are present then the seals need to be repositioned to provide a better seal. Wipe out any excess
moisture and reinstall evaporator core and case assembly.

7.

Verify the repair.

Thunderbird/Cougar

1.

Diagnosis # 1. Condensate carryover. Follow the Service Procedures listed in TSB 94-2-12.