Blower Motor Switch: Service and Repair

Temperature Control Module

Removal and Installation

1.

Remove A/C control.

2.

Remove the temperature control knob.

3.

Remove the hex-head screw retaining the temperature control module to the A/C control.

4.

Rotate the temperature control module clockwise until it is free from the retaining tabs on the A/C control and remove from the A/C control.

For installation, follow removal procedures in reverse order.