ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Fluid Pan, Gasket and Filter|Page 1220 > < Fluid Pan, Gasket and Filter|Page 1218
Page 2
background image

5. NOTE:  Be sure the cooler tube is fully seated in the body of the fitting before final tightening of the ferrule nut.

Install the 2 ferrule connectors finger tight onto each end of the tubing. Then tighten the nuts an additional 1-1/2 turns to seat the ferrules in the
connectors.

6. CAUTION:  The filter has a bypass valve in it. The red arrow on the filter indicates the direction of the fluid flow through the filter. The

filter must be installed in the fluid cooler return line with the red arrow pointing away from the transmission fluid cooler and toward the
transmission (the return line has fluid coming out of the cooler going to the transmission). If the fluid filter is not installed correctly, it
will cause internal transmission damage.
 

NOTE:  Do not install any rubber hoses or steel tubing with a bend entering the filter greater than 60 degrees.

Using suitable length of hose(s), install the filter. Tighten the clamps.

7. Connect the lower transmission cooler tube fitting.

^

Tighten to 28 Nm (21 lb-ft).

Fluid Pan, Gasket and Filter|Page 1220 > < Fluid Pan, Gasket and Filter|Page 1218