ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2462 > < Initial Inspection and Diagnostic Overview
Page 2
background image

ISO 9141 Communications Network

The ISO 9141 communications network is a single wire network. The ISO 9141 communications network does not permit intermodule
communication. When the scan tool communicates to modules on the ISO 9141 communication network, the scan tool must request all information;
the modules cannot initiate communications.

The following fault chart describes the specific ISO 9141 network failures and their resulting symptom:

ISO 9141 Network Communication Fault Chart

HS-CAN

The HS-CAN network uses an unshielded twisted pair cable of data (+) and data (-) circuits. The data (+) and the data (-) circuits are each regulated to
approximately 2.5 volts during neutral or rested network traffic. As bus messages are sent on the data (+) circuit, voltage is increased by
approximately 1.0 volt. Inversely, the data (-) circuit is reduced by approximately 1.0 volt when a bus message is sent. Multiple bus messages can be
sent over the network CAN circuits allowing multiple modules to communicate with each other.

The HS-CAN is a high speed communication network used for the instrument cluster (IC), PCM, the 4X4 control module, the restraints control
module (RCM), the OCSM communications and the smart junction box (SJB), and designed for real time information transfer and control. The
HS-CAN network will not communicate while certain faults are present, but will operate with diminished performance with other faults present. The
HS-CAN bus may remain operational when 1 of the 2 termination resistors are not present.

In the event that one of the 2 network circuits (HS-CAN + or HS-CAN -) becomes open to a module on the network, unreliable network
communication to all modules on the network may result. The module to which the network circuit is open may repeatedly send network messages
indicating there has been partial data received. This type of message is referred to as a negative-acknowledge (NACK) message.

Repeated NACK messages may "load" the network with too much activity causing intermittent no communication to other network modules and/or the
scan tool.

The following fault chart describes the specific HS-CAN network failures and their resulting symptom:

Initial Inspection and Diagnostic Overview|Page 2462 > < Initial Inspection and Diagnostic Overview