Ranger 2WD V6-3.0L (2008)
Positive Crankcase Ventilation Valve: Service and Repair
POSITIVE CRANKCASE VENTILATION (PCV) VALVE
Removal and Installation
1. Disconnect the PCV valve.
-
Disconnect the PCV valve electrical connector.
-
Disconnect the PCV valve tube from the PCV valve.
2. NOTE: A new PCV valve must be installed if removed from the cam cover.
Rotate to release and remove the PCV valve.
3. To install, reverse the removal procedure.