ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Discharging and Recovery Procedure|Page 2870 > < Refrigerant Discharging and Recovery Procedure|Page 2868
Page 2
background image

R-134a Manifold Gauge Set

SPECIAL TOOL(S)

1. Turn both valves on the R-134a Manifold Gauge Set counterclockwise to close the low - and high-pressure hoses to the center manifold and center

hose.

2. Remove the A/C charging valve cap from the low-pressure service gauge port valve.

3. Remove the A/C charging valve cap from the high-pressure service gauge port valve.

4. Connect the R-134a Manifold Gauge Set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port

valve.

Refrigerant Discharging and Recovery Procedure|Page 2870 > < Refrigerant Discharging and Recovery Procedure|Page 2868