Starter Solenoid: Testing and Inspection

4-143/2.3L ENGINE
Pull-In Test

1.

Disconnect field coil wire from M terminal of solenoid.

2.

Connect 12 volt battery between S terminal and M terminal. Test must be performed in less than 10 seconds.

3.

If pinion does not move outward, replace solenoid.

Hold-In Test

1.

Disconnect field coil wire from M terminal of magnetic switch.

2.

Connect 12 volt battery between S terminal and body.

3.

If pinion moves inward, replace solenoid.

Return Test

1.

Disconnect field coil wire from M terminal of magnetic switch.

2.

Connect 12 volt battery between M terminal and body. Test must be performed in less than 10 seconds.

3.

Pull pinion outward and release. If pinion does not quickly return to its original position, replace solenoid.