ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Coupler HVAC|Service and Repair > < Peanut Fitting|Page 7509
Page 2
background image

-

An O-ring seal is installed around the tube on the male block.

-

The female block is welded to the tube and is not adjustable.

-

Support the female fitting with a wrench to prevent twisting of the tubes.

-

The male block will pivot around the tube to allow for alignment with the female block during assembly.

-

When correctly assembled the male and female fittings should be flush.

-

Use only the O-ring seals listed in the Ford Master Parts Catalog for the peanut fitting.