ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Idle Mixture - Setting Procedure Revision|Page 1271 > < Idle Mixture - Setting Procedure Revision
Page 2
background image

I.

Install air cleaner assembly, but do not connect the flexible fresh air tube to the air cleaner duct and valve assembly. Using a propane
enrichment tool, Rotunda Tool T75L- 9600-A or equivalent, insert the tool hose approximately 3/4 of the way into the duct and valve
assembly. If necessary, secure the hose with tape, J. When the above Steps have been completed, proceed to Section II.

Idle Mixture - Setting Procedure Revision|Page 1271 > < Idle Mixture - Setting Procedure Revision