6. CAUTION:  Make sure that the screen is properly located. 

Clean and inspect the Electronic Pressure Control (EPC) limit circuit screen. Install the EPC limit circuit screen.

7. Install the (4) main control valve body check balls.

8. CAUTION:  The springs and valves are not interchangeable. Damage to transmission may occur. 

Install the dark color plastic converter relief valve and spring.

9. NOTE:  The springs and valves are not interchangeable.

Install the extension housing lube orifice and the metal silver Electronic Pressure Control (EPC) limit relief valve and spring.
1

Install the extension housing lube orifice.

2

Install the silver metal EPC limit relief valve and spring.