ford Workshop Repair Guides

Ford Ranger 4WD V6-30L Workshop Service and Auto Repair Manuals

Information Bus|Testing and Inspection > < Diagram Information and Instructions|Page 2476
Page 2
background image

HS-CAN Network Operation

The HS-CAN network communicates using bussed messages. The HS-CAN network uses an unshielded twisted pair cable, data bus (+) and data bus
(-) circuits. In addition to scan tool communication, this network allows sharing of information between all modules on the network.

The HS-CAN is a high speed communication network used for the following modules:
-

PCM

-

RCM

-

SJB

-

4X4 control module (if equipped)

-

Occupant classification system module (OCSM)

-

Instrument cluster (IC)

Network Termination

The CAN network uses a network termination circuit to improve communication reliability. The network termination of the CAN bus takes place
inside the termination modules by termination resistors. Termination modules are located at either end of the bus network. As network messages are
broadcast, in the form of voltage signals, the network voltage signals are stabilized by the termination resistors. Each termination module has a 120
ohm
 resistor across the positive and negative bus connection in the termination module. With 2 termination modules on each network, and the 120
ohm
 resistors located in a parallel circuit configuration, the total network impedance, or total resistance is 60 ohms.

Network termination improves bus message reliability by:
-

stabilizing bus voltage.

-

eliminating electrical interference.

Information Bus|Testing and Inspection > < Diagram Information and Instructions|Page 2476