ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Blower Motor|Description and Operation > < Defroster Register|Page 9203
Page 1
background image

Blower Motor: Specifications

Switch Setting 

Off ....................................................................................................................................................................................................  0.0 amps at 0.0 volts 
Low ............................................................................................................................................................................................  3.5-5.5 amps at 5.0 volts 
Medium-Low ..............................................................................................................................................................................  5.0-7.5 amps at 5.0 volts 
Medium-High ...........................................................................................................................................................................  7.0-9.5 amps at 10.0 volts 
High .......................................................................................................................................................................................  9.5-11.5 amps at 12.0 volts 

Blower Motor|Description and Operation > < Defroster Register|Page 9203