Expansion Block/Orifice Tube: Description and Operation

A/C Evaporator Core Orifice

NOTE:  The A/C evaporator core orifice should be replaced whenever an A/C compressor is replaced.

The A/C evaporator core orifice has the following characteristics:

-

color-coded red

-

has an orifice diameter of 1.6 mm (0.062 inch) 

-

is located in the A/C evaporator core inlet tube

-

has filter screens located on the inlet and outlet ends of the tube body

-

The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.

-

O-rings on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from by-passing the A/C evaporator core orifice.

-

Adjustment or repair cannot be made to the A/C evaporator core orifice assembly. It must be replaced as a unit.