background image

5. Install the exhaust manifold-to-EGR valve tube.

-

Tighten to 34 Nm (25 lb-ft).

6. Attach the differential pressure feedback EGR sensor to the exhaust manifold-to-EGR valve tube.

Exhaust Manifold - RH

Exhaust Manifold - RH

Removal

1. With the vehicle in NEUTRAL, position it on a hoist.

2. Remove the 2 exhaust manifold-to-dual converter Y-pipe nuts.

3. Remove the 6 nuts, the RH exhaust manifold and the gasket.

-

Discard the nuts and the gasket.

4. Remove and discard the 6 RH exhaust manifold studs.

Installation

1. Clean and inspect the RH exhaust manifold.

2. Install 6 new RH exhaust manifold studs.

-

Tighten to 12 Nm (106 lb-in).

3. Position a new gasket and the RH exhaust manifold and install 6 new nuts.

-

Tighten to 22 Nm (16 lb-ft).

4. Position the dual converter Y-pipe and install the 2 nuts.

-

To install, tighten to 40 Nm (30 lb-ft).