ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Hose/Line HVAC > < A/C Pressure Relief Valve
Page 1
background image

High Pressure Safety Valve HVAC: Description and Operation
High-Pressure Cutoff Switch

Air Conditioning

High-Pressure Cutoff Switch

The high-pressure cutoff switch is used to interrupt A/C operation in the event of high system discharge pressures.

-

The high-pressure cutoff switch is mounted on a Schrader valve-type fitting on the high-pressure side of the compressor manifold and tube
assembly (3.0L and 4.0L engines) or the compressor to condenser discharge line (2.3L engine only).

-

A valve depressor, located inside the threaded end of the high-pressure cutoff switch, presses on the Schrader valve stem.

-

This allows the high-pressure cutoff switch to monitor the compressor discharge pressure.

-

When the compressor discharge pressure rises, the switch contacts open, interrupting A/C operation. When the pressure drops, the contacts close.
For specifications regarding operating pressure(s), refer to Heating and Air Conditioning.

-

It is not necessary to recover the refrigerant to remove the pressure cutoff switch.

Hose/Line HVAC > < A/C Pressure Relief Valve