Taurus V6-182 3.0L DOHC SHO (1992)
Blower Motor: Testing and Inspection
Current Draw Test
BLOWER MOTOR CURRENT DRAW TEST
This test will determine if the blower motor is operating properly.
Blower Motor Current Draw Test - Schematic
1. Connect a 0.0-30.0 ampere ammeter, ground the negative lead of the blower motor and measure the motor current draw at the high-speed setting.
2. If the motor is operating properly, the current draw readings will be 20.0-25.0 Amps.