Temperature Gauge: Description and Operation
With Analog Instrument Cluster

DESCRIPTION 

The magnetic gauge movement consists of three primary coils, one of which is wound at a 90 degree angle to the other two. The coils form a
magnetic field which varies in direction according to the variable resistance of the sender unit connected between two of them. A primary magnet,
to which a shaft and pointer are attached, rotates to align to this primary field, resulting in pointer position. The bobbin/coil assembly is pressed
into a metal housing which has two holes for dial mounting. There is no adjustment, calibration or maintenance required for this gauge.